A study on detection of waterborne pathogens in hospital water systems for prevention of healthcare-associated infections: A prospective cross-sectional observational study.

Authors

  • Dr. Bidanchi Ch Marak Post Graduate, Department of Microbiology, Government Medical College, Suryapet, Telangana, India
  • Dr. S Ruth Ramya Assistant Professor, Department of Microbiology, Government Medical College, Suryapet, Telangana, India
  • Dr. Aditi Tomer Thakur Assistant Professor, Department of Microbiology, Government Medical College, Suryapet, Telangana, India
  • Dr. Taruni Gandhi Medical College image/svg+xml , Associate Professor, Department of Microbiology, Government Medical College, Suryapet, Telangana, India
  • Dr. R Kondal Rao Associate Professor, Department of Microbiology, Government Medical College, Suryapet, Telangana, India
  • Sultana Nadera Assistant Professor Department of Pathology, Government Medical College, Vikarabad, Telangana, India
  • Dr. Nagasaikaran Sade Intern, Department of General Medicine, Apollo Institute of Medical Sciences and Research, Hyderabad, Telangana, India

DOI:

https://doi.org/10.51168/xgm0fh58

Keywords:

Healthcare-associated infections, Hospital water systems, Pseudomonas aeruginosa, Biofilm, Waterborne pathogens, Microbiological surveillance

Abstract

Background

Hospital water systems can act as reservoirs of opportunistic waterborne pathogens. Biofilm formation within pipelines, taps and distal outlets promotes microbial persistence and increases healthcare-associated infection risk.

Objectives

To detect waterborne pathogens in hospital water systems and assess their relevance to healthcare-associated infection prevention.

Methods

This prospective cross-sectional observational study was conducted over 12 months in a tertiary care teaching hospital. Ninety environmental samples were examined: 35 tap water samples, 35 tap swabs, 5 reverse osmosis water samples, 10 air-conditioning water samples and 5 drinking water samples from intensive care units, wards, operation theatres, laboratories, dialysis areas and water outlets. Samples were processed using standard microbiological methods with Blood agar, MacConkey agar and Buffered Charcoal Yeast Extract agar. Isolates were identified by colony morphology, Gram staining and biochemical tests. Data were summarized using frequencies, percentages and a 95% confidence interval for culture positivity.

Results

Bacterial growth was detected in 19 of 90 samples, giving an overall contamination rate of 21.1% (95% CI: 14.0%-30.6%). Tap water had the highest positivity at 31.4%, followed by tap swabs at 22.9%. All isolates were Gram-negative bacilli. Pseudomonas aeruginosa predominated, followed by Klebsiella pneumoniae, Escherichia coli and Citrobacter freundii. Legionella pneumophila was not isolated. Reverse osmosis, air-conditioning and drinking water samples showed no growth. Contamination was concentrated at distal tap outlets, identifying potential environmental reservoirs.

Conclusion

Hospital water outlets, especially taps, were important environmental points for microbial contamination. Routine surveillance, timely maintenance and point-of-use infection control measures are essential to reduce water-associated infection risk.

Recommendations

Hospitals should implement structured water-safety monitoring, periodic flushing, tap outlet disinfection, documentation of corrective actions and integration of water surveillance with infection control audits.

References

1. Allegranzi B, Bagheri Nejad S, Combescure C, Graafmans W, Attar H, Donaldson L, et al. Burden of endemic health-care-associated infection in developing countries: systematic review and meta-analysis. Lancet. 2011;377(9761):228-241. doi:10.1016/S0140-6736(10)61458-4. PMID:21146207.https://doi.org/10.1016/S0140-6736(10)61458-4

2. Kanamori H, Weber DJ, Rutala WA. Healthcare outbreaks associated with a water reservoir and infection prevention strategies. Clin Infect Dis. 2016;62(11):1423-1435. doi:10.1093/cid/ciw122. PMID:26936670.

https://doi.org/10.1093/cid/ciw122

3. Decker BK, Palmore TN. The role of water in healthcare-associated infections. Curr Opin Infect Dis. 2013;26(4):345-351. doi:10.1097/QCO.0b013e3283630adf. PMID:23806897.https://doi.org/10.1097/QCO.0b013e3283630adf

4. Decker BK, Palmore TN. Hospital water and opportunities for infection prevention. Curr Infect Dis Rep. 2014;16(10):432. doi:10.1007/s11908-014-0432-y. PMID:25217106.https://doi.org/10.1007/s11908-014-0432-y

5. Hayward C, Brown MH, Whiley H. Hospital water as the source of healthcare-associated infection and antimicrobial-resistant organisms. Curr Opin Infect Dis. 2022;35(4):339-345. doi:10.1097/QCO.0000000000000842. PMID:35849524.

https://doi.org/10.1097/QCO.0000000000000842

6. Hayward C, Ross KE, Brown MH, Whiley H. Water as a source of antimicrobial resistance and healthcare-associated infections. Pathogens. 2020;9(8):667. doi:10.3390/pathogens9080667. PMID:32824770.

https://doi.org/10.3390/pathogens9080667

7. Loveday HP, Wilson JA, Kerr K, Pitchers R, Walker JT, Browne J. Association between healthcare water systems and Pseudomonas aeruginosa infections: a rapid systematic review. J Hosp Infect. 2014;86(1):7-15. doi:10.1016/j.jhin.2013.09.010. PMID:24289866.https://doi.org/10.1016/j.jhin.2013.09.010

8. Walker J, Moore G. Pseudomonas aeruginosa in hospital water systems. J Hosp Infect. 2015;89(4):324-327. doi:10.1016/j.jhin.2014.11.019. PMID:25623205.https://doi.org/10.1016/j.jhin.2014.11.019

9. Moradali MF, Ghods S, Rehm BHA. Pseudomonas aeruginosa lifestyle: a paradigm for adaptation, survival, and persistence. Front Cell Infect Microbiol. 2017;7:39. doi:10.3389/fcimb.2017.00039. PMID:28261568.

https://doi.org/10.3389/fcimb.2017.00039

10. Garvey MI, Bradley CW, Holden E. Waterborne Pseudomonas aeruginosa transmission in a hematology unit? Am J Infect Control. 2018;46(4):383-386. doi:10.1016/j.ajic.2017.10.013. PMID:29195780.

https://doi.org/10.1016/j.ajic.2017.10.013

11. Garvey MI, Wilkinson MAC, Holden KL, Martin T, Parkes J, Holden E. Tap out: reducing waterborne Pseudomonas aeruginosa transmission in an intensive care unit. J Hosp Infect. 2019;102(1):75-81. doi:10.1016/j.jhin.2018.07.039. PMID:30071267.https://doi.org/10.1016/j.jhin.2018.07.039

12. Borella P, Bargellini A, Marchegiano P, Vecchi E, Marchesi I. Hospital-acquired Legionella infections: an update on the procedures for controlling environmental contamination. Ann Ig. 2016;28(2):98-108. doi:10.7416/ai.2016.2088. PMID:27071320.

13. Nisar MA, Ross KE, Brown MH, Bentham R, Whiley H. Legionella pneumophila and protozoan hosts: implications for the control of hospital and potable water systems. Pathogens. 2020;9(4):286. doi:10.3390/pathogens9040286. PMID:32326561.https://doi.org/10.3390/pathogens9040286

14. Gholipour S, Nikaeen M, Mehdipour M, Mohammadi F, Rabbani D. Occurrence of chlorine-resistant Pseudomonas aeruginosa in hospital water systems: threat of waterborne infections for patients. Antimicrob Resist Infect Control. 2024;13(1):111. doi:10.1186/s13756-024-01468-4. PMID:39334230.

https://doi.org/10.1186/s13756-024-01468-4

Downloads

Published

2026-06-30

Issue

Section

Section of Microbiology Research

How to Cite

Bindanchi, M., Ruth, R., Thakur, D. A. T., Taruni, Kondal, R., Nadera, S., & Nagasaikaran, S. (2026). A study on detection of waterborne pathogens in hospital water systems for prevention of healthcare-associated infections: A prospective cross-sectional observational study. Student’s Journal of Health Research Africa, 7(2). https://doi.org/10.51168/xgm0fh58